Edward Shaw, Technical Manager at Tapflo Pumps UK, began his journey in the Pump Industry straight out of University, quickly advancing through various roles. Beginning as a Technical Sales Engineer, Edward progressed to Senior Applications Engineer and ultimately to Business Development Manager. His extensive experience spans the Oil & Gas, Marine, Industrial, and Food & Beverage pump markets. Edward's expertise lies in technical solutions and developing bespoke pump systems tailored to customer requirements. His in-depth knowledge and innovative approach enable him to create customised solutions that enhance efficiency and reliability. Edward's commitment to excellence and his ability to address complex technical challenges make him an invaluable resource for both our customers and team.

More articles by Edward Shaw
26/02/2020

Having trouble with your Active Pulsation Dampener? Our comprehensive guide will help you get up and running in no time.

Active Pulsation Dampener

Tapflo’s DT Active Pulsation Dampener has been designed to fit to our Air Operated Diaphragm Pumps to reduce the pulsations in the output.

Possible Faults

What are the main problems and possible faults when using a dampener?

Problem Possible Fault Possible Solution
The dampener doesn’t work The air pressure is too low Check if the set pressure is equal to the set pressure of the pump
The air connection is blocked Check/clean air supply connection
Muffler is blocked Check/clean/replace muffler
Dirt in the diaphragm chamber Remove debris from the chamber
Diaphragm breakdown Replace diaphragm
Liquid leaks from the dampener Screws on the housing are not properly tightened Check tightening torques
Damaged diaphragm Check/replace diaphragm
Tension/stress from the installation Adjust installation, eliminate stress & provide separate support for dampener
Liquid leaks from the muffler Diaphragm breakdown Replace diaphragm
Diaphragm Breakdown Wrong materials selected Contact us with detailed chemical composition of the product
System pressure is too high Use air treatment system to protect
Suction pressure is too high Make sure there is a pressure balance between the air and liquid side of the diaphragm